| 【Characteristics】 | 
                               
                                |  | (1) | The 08WX is a wireless transmission thermometer  with rechargeable batteries as power supply and its measurement area does not  have the limitation. The temperature measurement operation is convenient for  users. The outcome can be transferred to record acceptors or big screen. | 
                               
                                | (2) | HF-08WX has a self-checking systems for cold junction  compensation. When switch on, it shows the tested room  temperature. The opertor can judge whether the thermocouple at cold junction is  connected well and reliably and whether the temperature of reused thermocouple  is in the compensation range to ensure the high accuracy. | 
                               
                                | (3) | When thermocouple is immersed into the melt,  thermometer will capture the temperature of the melt,It  can avoid the effect on the test accuracy caused by the operation, such as time  of dipping thermocouples. | 
                               
                                | (4) | HF-08WX will buzz when capturing molten iron  temperature.Buzzing can remind operator of moving thermometer quickly and thus improve  application times of the thermocouple. | 
                               
                                | (5) | After buzzing, the measured  temperature can be locked on red LED and read by operator. | 
                               
                                | (6) | Instead of gazing at the screen, operators may  focus on the immersion depth and spray of the thermocouple to ensure their  safety. | 
                              
                                |  | (7) | The wireless systerm can send out measurement  results when detecting other frequency signals. The last second figure of the red  LED screen will be flashed when? receiving feedback signals. | 
                              
                                |  | (8) | Within 1 minute after arresting peak-temperature, the  power will be off automatically, which can help to avoid the useless  consumption and the reduction of recharging times so as to extend the life span  of battery. | 
                              
                                |  | (9) | When switch on , the power remained are displayed,  which will remind the operator of charging the battery soon so that the  measuring accuracy can be kept. | 
                              
                                |  | (10) | The specification of recharge battery is 3000mA/h.  Over l000 times measurement can be accessed for the new battery when fully  charged. Adaptor will charge the battery within 5 hours. |